Tritech is supplying new types of RO membrane made of polymer and nano powder compound.
TriTech® Polymer and Nano Compounded (PNC) RO Membranes
Performance of Tritech® PNC RO Membrane
Tritech® PNC RO membrane can work stably in the following condition:
-
Maximum operation pressure: 1000 psi (69 bar)
-
Maximum pressure difference: 15 psi (1.0 bar)
-
Highest working temperature: 50°C
-
pH range of inlet water: 2 - 11
-
pH range under temporary backwash condition: 1 - 12
-
Maximum SDI of inlet water: SDI 5
Performance of Tritech® PNC RO Membrane for Seawater Desalination
Parameters |
Tritech® PNC RO Membrane |
Size (inches) |
4”x40” |
8”x40” |
Working Pressure (MPa) |
5.5-6.0 |
5.5-6.0 |
Production (m³/d) |
6.0-7.5 |
30-35 |
Nominal Rejection (%) |
99.2 |
99.5 |
Nominal Area (m²) |
7.2 |
34.4 |
Quality of Permeates by Tritech® PNC RO Membrane
Test Results of Seawater Desalination by Using Tritech® PNC RO Membrane
S/N |
Parameter |
Unit |
Specification |
Test results by using PNC RO Membrane |
1 |
Chromaticity |
degree |
<15 |
<5 |
2 |
Turbidity |
NTU |
<1 |
0.22 |
3 |
Odour |
- |
N/A |
N/A |
4 |
Visible Suspension |
- |
N/A |
N/A |
5 |
pH |
- |
6.5 – 8.5 |
6.82 |
6 |
Total Hardness |
As CaCO3 (mg/L) |
<450 |
12.4 |
7 |
Iron |
mg/L |
<0.3 |
<0.004 |
8 |
Maganese |
mg/L |
<0.1 |
<0.002 |
9 |
Copper |
mg/L |
<1.0 |
<0.002 |
10 |
Zinc |
mg/L |
<1.0 |
<0.002 |
11 |
Phenol |
mg/L |
<0.002 |
<0.002 |
12 |
Sulfate |
As SO42- (mg/L) |
<250 |
3.72 |
13 |
Chloride |
As Cl - (mg/L) |
<250 |
226 |
14 |
Total Dissolved Solids |
mg/L |
<1000 |
326 |
15 |
Fluoride |
As F- (mg/L) |
<1.0 |
<0.02 |
16 |
Cyanide |
mg/L |
<0.05 |
<0.002 |
17 |
Arsonium |
mg/L |
<0.05 |
<0.005 |
18 |
Selenium |
mg/L |
<0.01 |
<0.0003 |
19 |
Mercury |
mg/L |
<0.001 |
<0.0004 |
20 |
Codminium |
mg/L |
<0.005 |
<0.0002 |
21 |
Chromium |
mg/L |
<0.05 |
<0.004 |
22 |
Lead |
mg/L |
<0.01 |
<0.0005 |
23 |
Aluminum |
mg/L |
<0.2 |
0.0054 |
24 |
Ammonia |
mg/L |
<20 |
<0.02 |
25 |
Oxygen Demand |
mg/L |
<3 |
1.09 |
Conclusion |
Satisfied |
Available Sizes of TriTech® PNC RO Membranes
Model Number |
Size (inches) |
Test Pressure (MPa) |
Production |
Nominal Rejection (%) |
Nominal Areas (m²) |
(GPM) |
(m³/d) |
PNC-4040 |
4”x40” |
5.5 |
27-33 |
6.0-7.5 |
99.2 |
8.0 |
PNC-8040 |
8”x40” |
5.5 |
132-155 |
30.0-35.0 |
99.5 |
46.0 |
PNC-8080 |
8”x60” |
5.5 |
203-220 |
46.0-50.0 |
99.5 |
52.0 |
Tritech® Super low pressure Polymer and Nano Compounded (SPNC) RO Membrane
Size Available of SPNC RO Membrane
Tritech® SPNC RO membrane is further improved products which are proudly presented by Tritech Water Technologies Pte Ltd.
TriTech® SPNC RO Membranes
Model Number |
Size (inches) |
Test Pressure (MPa) |
Production (m³/d) |
Nominal Rejection (%) |
Nominal Areas (m²) |
SPNC HD4040 |
4” x 40” |
3.0-4.0 |
6.0-7.5 |
99.2 |
7.2 |
SPNC HD8040 |
8” x 40” |
3.0-4.0 |
33.0-36.0 |
99.5 |
44.4 |
SPNC HK4040 |
4” x 40” |
0.6-1.0 |
8.0-9.0 |
99.5 |
10.5 |
SPNC HK8040 |
8” x 40” |
0.6-1.0 |
35.8-38.0 |
99.5 |
46.5 |
Performance of Tritech® SPNC RO Membrane
Comparison between Polymer, TriTech® PNC and SPNC RO Membranes for Seawater Desalination
Parameters |
Normal Polymer RO
Membrane |
Tritech® PNC RO
Membrane |
Tritech® SPNC RO
Membrane |
Size (inches) |
4”x40” |
8”x40” |
4”x40” |
8”x40” |
4”x40” |
8”x40” |
Working Pressure
(MPa) |
5-8 |
5-8 |
5.5 - 6.0 |
5.5 - 6.0 |
1.0-1.5 |
1.0-1.5 |
Production
(m³/d) |
4.5 |
18.9 |
6 - 7.5 |
30 - 35 |
6.0-9.0 |
33.0-39.0 |
Nominal Rejection (%) |
99.6 |
99.6 |
99.5 |
99.5 |
99.5 |
99.5 |
Nominal Area (m²) |
6.8 |
13.9 |
7.2 |
34.4 |
7.2-10.5 |
44.4-46.5 |
Tritech® PNC and SPNC RO membranes have many advantages over the normal polymer membrane in the market. For example, Tritech® PNC and SPNC RO membranes have higher permeate, higher strength, higher flexibility, less stringent requirement for the inlet water, less requirement of the maintenance including backwash, and longer working life span.
Please contact us for more information
|